Huawei FusionServer 5288 V3 rack server Overview

Huawei new-generation FusionServer 5288 V3 rack server delivers ultra-large local storage capacity, flexible resource expansion and high computing performance in 4U spaces. This rack server is ideal choice for cold date and cloud storage, video surveillance and big data applications. Huawei FusionServer 5288 V3 supports up to 2 Intel Xeon E5-2600 v3 Series processors, 16 DDR4 DIMMS, 6 PCIe 3.0 slots and 40 SAS or SATA disks. Moreover, Huawei FusionServer 5288 V3 uses dynamic energy management technology to adjust server operating status dynamically and limit power consumption to an optimal level, and uses proportion integration differentiation to control heat dissipation and fan speed adjustment policies, implements stepless speed regulation and on-demand allocation of heat dissipation resources, and minimizes power consumption and noise.

Quick Specs

Figure 1 shows the appearance of Huawei FusionServer 5288 V3 rack server.

Table 1 shows the Quick Specs.

Product

Huawei FusionServer 5288 V3 rack server

Form factor

4 U rack server

Number of processors

One or two

Processor model

Intel Xeon E5-2600 v3/v4 series processors

Number of DIMM slots

8 or 16 slots for DDR4 RDIMMs or LRDIMMs

Memory

16 DDR4 RDIMMs/LRDIMMs

Internal Storage

5288 V3 with 40 hard disks
Front:

24 x 3.5-inch SAS/SATA HDDs

Rear:

16 x 3.5-inch SAS/SATA HDDs
14 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDs or SAS/SATA HDDs
12 x 3.5-inch SAS/SATA HDDs + 4 x 2.5-inch SSDs or SAS/SATA HDDs

5288 V3 with 28 hard disks
Front:

24 x 3.5-inch SAS/SATA HDDs

Rear:

4 x 3.5-inch SAS/SATA HDDs
2 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDs or SAS/SATA HDDs
4 x 2.5-inch SSDs or SAS/SATA HDDs

RAID

RAID 0, 1, 10, 5, 50, 6, or 60
Configured with a supercapacitor for power-off protection for the cache (optional)
RAID state transition, configuration memory, self-diagnosis, and web-based remote configuration

LOM Network Ports

Supported network configurations:

2 GE electrical ports, supporting Network Controller Sideband Interface (NC-SI), Wake on LAN (WoL), and pre-boot execution environment (PXE)
4 GE electrical ports, supporting NC-SI, WoL, and PXE
2 x 10 GE optical ports, supporting NC-SI and PXE
2 x 10 GE electrical ports, supporting NC-SI, WoL, and PXE
2 GE electrical ports and 2 x 10 GE optical ports, supporting NC-SI, WoL, and PXE

PCIe Expansion

Up to 6 PCIe 3.0 slots

Fan Modules

Hot-swappable fan modules in N+1 redundancy mode

Power Supply Units

2 hot-swappable PSUs in 1+1 redundancy mode

Management

Uses Huawei Hi1710 management chip and independent ports
Supports standard management interfaces, such as SNMP and IPMI; provides GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring
Supports Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft System Center, and Nagios

Operating Temperature

5C to 40C (41F to 104F), ASHRAE Class A3 compliant

Dimensions (H x W x D)

175 mm x 447 mm x 748 mm (6.89 in. x 17.60 in. x 29.45 in.)

Product Details

Figure 2 shows the front panel of Huawei FusionServer 5288 V3 rack server.

Note:

Network port link status indicators

USB 2.0 port

Hard disk fault indicator

Hard disk activity indicator

Hard disks (numbered 0 to 23 from top to bottom and from left to right)

Fault diagnosis LED

Health indicator

UID button/indicator

Power button/indicator

Figure 3 shows the back panel of Huawei FusionServer 5288 V3 rack server.

Note:

Rear hard disk

Hard disk fault indicator

Hard disk activity indicator

I/O module

PSU port

PSU indicator

PSU

Serial port

VGA port

Connectivity status indicator

Management network port (Mgmt)

Data transmission status indicator

USB 3.0 port

UID indicator

PCIe slot

LAN on motherboard (LOM)

Rear hard disk

Compare to Similar Items

Table 3 shows the comparison of Huawei FusionServer 5288 V3 rack server, Huawei FusionServer RH5885 V3 Rack Server and Huawei FusionServer RH5885H V3 Rack Server.

Product

Huawei FusionServer 5288 V3 rack server

Huawei FusionServer RH5885 V3 Rack Server

Huawei FusionServer RH5885H V3 Rack Server

Form factor

4 U rack server

4U rack server

4U rack server

Number of processors

One or two

2 or 4

2 or 4

Processor model

Intel Xeon E5-2600 v3/v4 series processors

Intel Xeon E7-4800 v3/v4 or E7-8800 v3/v4 processors, with an L3 cache capacity of 60 MB maximum

Intel Xeon E7-4800 v3/v4 or E7-8800 v3/v4 processors, with an L3 cache capacity of 60 MB maximum

Number of DIMM slots

8 or 16 slots for DDR4 RDIMMs or LRDIMMs

48 DIMMs, up to 3 TB (64 GB DIMMs)

96 DIMMs, up to 6 TB (using 64 GB DIMMs)

Memory

16 DDR4 RDIMMs/LRDIMMs

48 DIMMs

96 DIMMs

Internal Storage

5288 V3 with 40 hard disks
Front:

24 x 3.5-inch SAS/SATA HDDs

Rear:

16 x 3.5-inch SAS/SATA HDDs
14 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDs or SAS/SATA HDDs
12 x 3.5-inch SAS/SATA HDDs + 4 x 2.5-inch SSDs or SAS/SATA HDDs

5288 V3 with 28 hard disks
Front:

24 x 3.5-inch SAS/SATA HDDs

Rear:

4 x 3.5-inch SAS/SATA HDDs
2 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDs or SAS/SATA HDDs
4 x 2.5-inch SSDs or SAS/SATA HDDs

8 or 23 x 2.5-inch SAS/SATA HDDs or SSDs, or 8 x 2.5-inch SAS/SATA HDDs + 4 x 2.5-inch NVMes

8 or 23 x 2.5-inch SAS/SATA HDDs or SSDs, or 8 x 2.5-inch SAS/SATA HDDs + 4 x 2.5-inch NVMes

Get more information

Do you have any question about the Huawei FusionServer 5288 V3 rack server

Contact us now via

Live Chat or sales@netseg.me.

Be the first to review “Huawei FusionServer 5288 V3 rack server”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Customer Reviews

(0)
5 stars
4 stars
3 stars
2 stars
1 stars

No reviews yet.

×

Write a Review

Huawei FusionServer 5288 V3 rack server Specification

Huawei FusionServer 5288 V3 rack server Specifications

Form factor

4 U rack server

Number of processors

One or two

Processor model

Intel Xeon E5-2600 v3/v4 series processors

Number of DIMM slots

8 or 16 slots for DDR4 RDIMMs or LRDIMMs

Memory

16 DDR4 RDIMMs/LRDIMMs

Internal Storage

5288 V3 with 40 hard disks
Front:

24 x 3.5-inch SAS/SATA HDDs

Rear:

16 x 3.5-inch SAS/SATA HDDs

14 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDs or SAS/SATA HDDs

12 x 3.5-inch SAS/SATA HDDs + 4 x 2.5-inch SSDs or SAS/SATA HDDs


5288 V3 with 28 hard disks
Front:

24 x 3.5-inch SAS/SATA HDDs

Rear:

4 x 3.5-inch SAS/SATA HDDs

2 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDs or SAS/SATA HDDs

4 x 2.5-inch SSDs or SAS/SATA HDDs

RAID

RAID 0, 1, 10, 5, 50, 6, or 60

Configured with a supercapacitor for power-off protection for the cache (optional)

RAID state transition, configuration memory, self-diagnosis, and web-based remote configuration

LOM Network Ports

Supported network configurations:

2 GE electrical ports, supporting Network Controller Sideband Interface (NC-SI), Wake on LAN (WoL), and pre-boot execution environment (PXE)

4 GE electrical ports, supporting NC-SI, WoL, and PXE

2 x 10 GE optical ports, supporting NC-SI and PXE

2 x 10 GE electrical ports, supporting NC-SI, WoL, and PXE

2 GE electrical ports and 2 x 10 GE optical ports, supporting NC-SI, WoL, and PXE

PCIe Expansion

Up to 6 PCIe 3.0 slots

Fan Modules

Hot-swappable fan modules in N+1 redundancy mode

Power Supply Units

2 hot-swappable PSUs in 1+1 redundancy mode

Management

Uses Huawei Hi1710 management chip and independent ports

Supports standard management interfaces, such as SNMP and IPMI; provides GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring

Supports Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft System Center, and Nagios

PCIe expansion

A maximum of six PCIe slots.

PSU

Two hot-swappable PSUs in 1+1 redundancy

Supports 750 W and 1200 W Platinum AC PSUs.

Supported OS

CentOS

Citrix XenServer

Microsoft Windows Sever

Red Hat Enterprise Linux

SUSE Linux Enterprise Server

VMware ESXi

Certification

CE, UL, FCC, CCC, and RoHS

Installation suite

Guide rails

Hold rails and cable management arm (optional)

Operating Temperature

5C to 40C (41F to 104F), ASHRAE Class A3 compliant

Dimensions (H x W x D)

175 mm x 447 mm x 748 mm (6.89 in. x 17.60 in. x 29.45 in.)