Huawei RH 1288A V2 server Overview

Huawei RH1288A V2 rack server is designed for compute intensive and cloud applications. This high-performance 1U rack server supports 2 Intel Xeon E5-2600 V2 series processors, 8*DDR3 RDIMMs/LRDIMMS slots, 8*2.5 SAS/SATA HDDs or SSDs or 4*3.5 SAS or SATA HDDSs. This server supports 2 GE ports without occupying any PCIe slots, improving network availability. Moreover, Dynamic energy-saving and power-capping technologies limit server power consumption to a preset threshold, improving overall energy efficiency.

Quick Specs

Figure 1 shows the appearance of Huawei RH 1288A V2 server.

The RH1288A V2 has the following two models:

The RH1288A V2-8S supports eight 2.5-inch SAS HDDs, SATA HDDs, or SSDs. Figure 1-1 shows the RH1288A V2-8S appearance.

The RH1288A V2-4L supports four 3.5-inch SAS or SATA HDDs. Figure 1-2 shows the RH1288A V2-4L appearance.

Figure 1-1  RH1288A V2-8S appearance. 

Figure 1-2  RH1288A V2-8S appearance.

Table 1 shows the Quick Specs.

Product

Huawei RH 1288A V2 server

Processors

1 or 2 Intel Xeon E5-2600 v2 series processors

Memory

8 DDR3 RDIMMs/LRDIMMs

Internal Storage

Hard disk configurations:
8 x 2.5-inch SAS/SATA HDDs or SSDs
4 x 3.5-inch SAS or SATA HDDs

RAID Support

RAID 0, 1, 10, 5, 50, 6, or 60
  Supercapacitor
  RAID state migration, configuration memory, self-diagnosis, and web-based remote configuration

LOM Network Ports

Network configuration: 2 x GE electrical ports

PCIe Expansion

Up to 3 PCIe slots

Fan Modules

5 hot-swappable fan modules in N+1 redundancy mode; each fan module consists of two counter-rotating fans

PSUs

2 hot-swappable PSUs in 1+1 redundancy mode

Management

Uses Huawei Hi1710 management chip and independent ports, supports standard management interfaces, such as SNMP and IPMI, and provides a GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring
Supports Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft SystemCenter, and Nagios

Operating Temperature

5C to 35C (41F to 95F)

 Product Details

Figure 2 shows the front panel of Huawei RH 1288A V2 server.

Figure 2-1  RH1288A V2-8S front view.

Note:

UID button/indicator

Power button/indicator

USB port

USB port

Ethernet port indicator 1

Ethernet port indicator 2

Healthy indicator

VGA port

Hard disk

 

Captive screw

Hard disk fault indicator

Hard disk active indicator

Label (including the ESN label)

Built-in DVD-ROM drive

Hard disk slot label

 

 

Figure 2-2  RH1288A V2-4L front view. 

UID button/indicator

Power button/indicator

USB port

USB port

Ethernet port indicator 1

Ethernet port indicator 2

Healthy indicator

Hard disk

Captive screw

 

Hard disk fault indicator

Hard disk active indicator

Label (including the ESN label)

Hard disk slot label

 

Figure 3 shows the back panel of Huawei RH 1288A V2 server.

Note:

Connection status indicator

GE port

Data transmission status indicator

GE port

UID indicator

Management network port (Mgmt)

USB port

USB port

VGA port

 

Serial port

PSU power port

PSU indicator

PSU

PSU power port

PSU indicator

16

PSU

Compare to Similar Items

Table 3 shows the comparison of Huawei RH 1288A V2 server and Huawei RH1288 V2 Rack Server.

Product

Huawei RH 1288A V2 server

Huawei RH1288 V2 Rack Server

Processors

1 or 2 Intel Xeon E5-2600 v2 series processors

One or two Intel Xeon E5-2600 or E5-2600 v2 series processors

Memory

8 DDR3 RDIMMs/LRDIMMs

24 DDR3 RDIMMs/LRDIMMs

Internal Storage

Hard disk configurations:
8 x 2.5-inch SAS/SATA HDDs or SSDs
4 x 3.5-inch SAS or SATA HDDs

Hard disk configurations:
8 x 2.5-inch SAS/SATA HDDs or SSDs
4 x 3.5-inch SAS or SATA HDDs

LOM Network Ports

Network configuration: 2 x GE electrical ports

Network configuration: two or four GE ports or two 10 GE ports

Fan Modules

5 hot-swappable fan modules in N+1 redundancy mode; each fan module consists of two counter-rotating fans

Seven hot-swappable fan modules in N+1 redundancy mode
Each fan module consists of two counter-rotating fans.

Get more information

Do you have any question about the Huawei RH 1288A V2 server

Contact us now via

Live Chat or sales@netseg.me.

Be the first to review “Huawei RH 1288A V2 server”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Customer Reviews

(0)
5 stars
4 stars
3 stars
2 stars
1 stars

No reviews yet.

×

Write a Review

Huawei RH 1288A V2 server Specification

Huawei RH 1288A V2 server Specifications

Technical Specifications

Form factor

1 U rack server

Processor

Up to two Intel Xeon E5-2600 v2 series processors:

Number of cores per processor: 10 cores (2.4 GHz), 8 cores (2.6 GHz), 6 cores (2.6 GHz), and 4 cores (2.5 GHz)

Number of QPI links: 2

Maximum transmission speed per QPI link: 8.0 GT/s

Maximum memory speed: 1866 MHz

Maximum L3 cache capacity: 25 MB

Up to two Intel Xeon E5-2600 series processors:

Number of cores per processor: 8 cores (2.2 GHz), 6 cores (2.5 GHz), and 4 cores (2.4 GHz)

Number of QPI links: 2

Maximum transmission speed per QPI link: 8.0 GT/s

Maximum memory speed: 1600 MHz

Maximum L3 cache capacity: 20 MB

Chipset

Intel C602

DIMM

Up to 8 DIMM slots (4 DIMMs per processor) for installing either RDIMMs or LRDIMMs

8 x 32 GB RDIMMs for two processors, with a maximum memory capacity of 256 GB

8 x 32 GB LRDIMMs for two processors, with a maximum memory capacity of 256 GB

Maximum memory speed: 1866 MHz (E5-2600 v2)

Data protection measures: ECC, memory mirroring, Single Device Data Correction (SDDC), memory sparing, and lockstep

Storage

The RH1288A V2 supports the following hard disk configurations:

RH1288A V2-8S: eight front 2.5-inch SAS HDDs (7.2 TB), SATA HDDs (8 TB), or SSDs (4.8 TB)

RH1288A V2-4L: four front 3.5-inch SAS HDDs (4 TB) or SATA HDDs (16 TB)

Hard disks are hot-swappable.

The server supports RAID 0, 1, 10, 1E, 5, 50, 6, and 60. It protects cache data from power failures, and supports RAID state migration, RAID configuration memory, self-diagnosis, and web-based configuration.

The mainboard can be configured with a SAS adapter or SAS RAID controller card (with a maximum of 1 GB cache) to improve hard disk storage performance and ensure user data security.

The RAID controller card does not occupy a standard PCIe slot, improving system scalability.

Network port

Two GE ports (Intel I350) on the mainboard, supporting NC-SI, WOL, and PXE

PCIe slot

The server provides three PCIe slots: one for a full-height full-length PCIe card, one for a half-height half-length PCIe card, and one for a non-standard RAID controller card.

One Huawei PCIe intelligent network interface card (iNIC), which improves the I/O bandwidth and throughput.

One Huawei SSD card, which greatly improves I/O performance for search, cache, and download services.

NVS315 GPU.

Port

Ports on the front panel:

Two USB 2.0 ports

One DB15 video port (provided by the RH1288A V2-8S)

Ports on the rear panel:

Two USB 2.0 ports

One DB15 video port

One DB9 serial port

One RJ45 system management port

One built-in USB port (for the embedded system management program)

Fan module

Five hot-swappable fan modules, tolerating the failure of a single fan. Each fan module consists of two counter-rotating fans.

PSU

Two hot-swappable 460 W AC PSU in redundancy mode, supporting efficiency of up to 94 percent.

System management

UEFI

Huawei iBMC: supports Intelligent Platform Management Interface (IPMI), Serial over LAN (SOL), KVM over IP, and virtual media, and provides one 10/100/1000M RJ-45 management network port.

NC-SI

Security

Power-on password

Administrator password

GPU

The mainboard integrates the SM750 display chip and provides 32 MB display memory. The maximum resolution is 1920 pixels x 1200 pixels at 60 Hz with 16 M colors.

Physical Specifications

Dimensions (H x W x D)

43.6 mm x 447 mm x 740 mm (1.78 in. x 17.05 in. x 29.13 in.)

Installation dimensions

The RH1288A V2 fits into a common rack complying with the IEC 297 standard.

Rack width: 19 in.

Rack depth: > 1000 mm (39.37 in.)

Guide rail installation requirements are as follows:

L-shaped guide rails: apply only to Huawei racks.

Adjustable guide rail: The distance between the front rear mounting bars is 557 mm to 862 mm.

Power rating

460 W

Weight in full configuration

Net weight:

RH1288A V2-8S: 19.6 kg

RH1288A V2-4L: 20 kg

Packaging materials: 5.3 kg (11.69 lb)

Input voltage

AC: 100-240 V AC (with an input frequency of 50 Hz or 60 Hz)

240 V HV DC: 192-288 V DC

NOTE:

The recommended current specification for the external power circuit breaker connected to the RH1288A V2 is 32 A.

Temperature

Operating temperature: 5C to 35C (41F to 95F)

Storage temperature: 40C to +65C (40F to +149F)

Temperature change rate: < 20C/h (36F/h)

Long-term storage temperature: 21C to 27C (69.8F to 80.6F)

Altitude

3000 m (9842.40 ft) When the altitude is higher than 900 m (2952.72 ft), the operating temperature decreases by 1C (33.8F) per 300 m (984.24 ft).

Humidity

Operating humidity: 8% RH to 90% RH (non-condensing)

Storage humidity: 5% RH to 95% RH (non-condensing)

Humidity change rate: < 20% RH/hour

Long-term storage humidity: 30% RH to 69% RH (non-condensing)

Acoustic Noise

The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23C (73.4F) ambient environment. Noise emissions are measured in accordance with ISO 7999 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).

Idle:

LWAd: 5.9Bels

LpAm: 43dBA

Operating:

LWAd: 6.7Bels

LpAm: 50.1dBA

NOTE:

The actual sound levels generated during server operating vary depending on the server configuration, load, and ambient temperature.

 

 